新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > corrosive chemical dispensing micro flowmeter
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

corrosive chemical dispensing micro flowmeter

Date:2017-02-01 source:
  corrosive chemical dispensing micro flowmeter  

email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD.is a family company and it has more than 30 yearshistory. We are specialized in research of high quality flow meters, such as mircoflow meter,oval gear flow meter ,coriolis mass flow meter,electromagnetic flowmeter,piston flow meter, spur gear flow meter,gear pump,gear metering pump andso on. We devote ourselves to break the technology monopoly of foreigncountries. Our micro flow meter can replace Kracht, OVAL, SIKA and OMAGEforeign brands and so on. We have export our flow meters into more than 100countries and Shanghai JSN Micro Flow Meter CO.,LTD has already been a famous Automationinstrumentation company.

 corrosive chemical dispensing micro flowmeter

corrosive chemical dispensing micro flowmeter

Ovalgear flow meter  is widely used inpetroleum, chemical and hydraulic industries due to its advantages of highprecision, simple installation, stable performance and goodrepeatability.However, the Oval gear flow meter that can be produceddomestically can only be applied due to the impatience of high pressure In thelow pressure occasion, the high pressure measurement occasion can only rely onthe foreign imported high pressure flowmeter.Therefore, the research of thehigh pressure Oval gear flow meter will help to expand the domestic applicationof the Oval gear flow meter and promote the development of the domestic flowmeasurement. Deep instrumentation independent research and development of the Ovalgear flow meter pressure up to 1000bar, it can be said has reached a higherlevel in the world, and obtain measurement certificate.

A newgeneration of deep base Oval gear flow meter has been officially listed on thenational market in early 2017. This is a newly developed volumetric flowmeteror a positive displacement flowmeter developed by QWEN engineers combiningadvanced technologies both at home and abroad. Deep base of the exhibitionhall, will see the flow meters on behalf of the generation (such as DTO, CX-FM,CX-M, CX-G series), also see the base depth meter in the continuoustechnological innovation. Is characterized by small flow, a large range, highprecision, long life. Through several iterations, the quality of the product isgetting higher and higher, while the price is less than one-third of the importedbrands, can be said that the Shanghai base deep mirco flow meter Successfuldevelopment, domestic customers do not have to worry about delivery, sale andother issues.

micro flowmeter

corrosive chemical dispensing micro flowmeter

The Ovalgear flow meter is composed of a flow transmitter and a counting mechanism. Themain part of the transmitter consists of a measuring chamber equipped with apair of gear rotors and a sealing coupling. The counting mechanism consists ofa speed reducing mechanism, a precision adjusting mechanism, a counter and apower Pulse transmitter and other components.

 corrosive chemical dispensing micro flowmeter

corrosive chemical dispensing micro flowmeter

Technicaldata of CX-M Series micro oval Oval gear flow meter

Model

Flow  range

Accuracy

Connection  size

CX-M2

0.5~150ml/min

0.5%

G1/8"

CX-M3

3~300ml/min

0.5%

G1/8"

CX-M5

5~1000ml/min

0.5%

G1/8"

CX-M6

0.5~100L/H

0.5%

G1/4"

CX-M9

6~600L/H

0.5%

G1/4"

CX-M12

0.3~30L/Min

0.5%

G1/2"

CX-M25

0.5~100L/Min

0.5%

G1"


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.
Share to:


© 2016 Shanghai JSN Micro Flow Meter CO.,LTD  All rights reserved  Shanghai ICP preparation 07036704-1Map | Contact